41-765-002 -
Pickering Interfaces Ltd.
The 41/43-765-002 is a 12-channel Analog Output Module designed to meet the requirements of industrial control applications utilizing current loops 4 – 20mA. It consists of up to four 16-bit, digital-to-analogue converters (DAC), capable of creating four current outputs each. Output current within 0mA - 4mA and 20mA - 24mA, give the ability to simulate error or extra signaling conditions. The ±24mA mode gives the ability to simulate either sourcing or sinking sensor.
-
41-765-003 -
Pickering Interfaces Ltd.
The 41/43-765-003 is an 8-channel Analog Output Module designed to meet the requirements of industrial control applications utilizing current loops 4 – 20mA. It consists of up to four 16-bit, digital-to-analogue converters (DAC), capable of creating four current outputs each. Output current within 0mA - 4mA and 20mA - 24mA, give the ability to simulate error or extra signaling conditions. The ±24mA mode gives the ability to simulate either sourcing or sinking sensor.
-
41-765-004 -
Pickering Interfaces Ltd.
The 41/43-765-004 is an 4-channel Analog Output Module designed to meet the requirements of industrial control applications utilizing current loops 4 – 20mA. It consists of up to four 16-bit, digital-to-analogue converters (DAC), capable of creating four current outputs each. Output current within 0mA - 4mA and 20mA - 24mA, give the ability to simulate error or extra signaling conditions. The ±24mA mode gives the ability to simulate either sourcing or sinking sensor.
-
43-765-004 -
Pickering Interfaces Ltd.
The 41/43-765-004 is an 4-channel Analog Output Module designed to meet the requirements of industrial control applications utilising current loops 4 – 20mA. It consists of up to four 16-bit, digital-to-analogue converters (DAC), capable of creating four current outputs each. Output current within 0mA - 4mA and 20mA - 24mA, give the ability to simulate error or extra signalling conditions. The ±24mA mode gives the ability to simulate either sourcing or sinking sensor.
-
43-765-001 -
Pickering Interfaces Ltd.
The 41/43-765-001 is a PXI/PXIe 16-channel Analog Output Module designed to meet the requirements of industrial control applications utilising current loops 4 – 20mA. It consists of up to four 16-bit, digital-to-analogue converters (DAC), capable of creating four current outputs each. Output current within 0mA - 4mA and 20mA - 24mA, give the ability to simulate error or extra signalling conditions. The ±24mA mode gives the ability to simulate either sourcing or sinking sensor.
-
43-765-002 -
Pickering Interfaces Ltd.
The 41/43-765-002 is a 12-channel Analog Output Module designed to meet the requirements of industrial control applications utilising current loops 4 – 20mA. It consists of up to four 16-bit, digital-to-analogue converters (DAC), capable of creating four current outputs each. Output current within 0mA - 4mA and 20mA - 24mA, give the ability to simulate error or extra signalling conditions. The ±24mA mode gives the ability to simulate either sourcing or sinking sensor.
-
43-765-003 -
Pickering Interfaces Ltd.
The 41/43-765-003 is an 8-channel Analog Output Module designed to meet the requirements of industrial control applications utilising current loops 4 – 20mA. It consists of up to four 16-bit, digital-to-analogue converters (DAC), capable of creating four current outputs each. Output current within 0mA - 4mA and 20mA - 24mA, give the ability to simulate error or extra signalling conditions. The ±24mA mode gives the ability to simulate either sourcing or sinking sensor.
-
Ametek Scientific Instruments
Potentiostats control a voltage and measure a resulting current. The Control Amplifier outputs power to the counter electrode (also called auxiliary electrode). A feedback loop is established to control the cell potential between the reference and working electrode. This voltage is measured by the input electrometer, that has a high impedance. This current is then measured between the working and counter electrodes while this potential is maintained at the working electrode and reference electrode.
-
AMPI-530 -
Amperis sl
Measurement of short-circuit loop ; Testing of differential, general and selective protections for differential current ; Measurement of insulation resistance ; Up to 10GΩ ; Voltages: 50 V, 100 V, 250 V, 500 V, 1000 V ; Measurement of earth resistance ; Bi-directional continuity test on PE cables, phase sequence ; Measurement and recording of voltage, frequency, alternating current, cosϕ, power, harmonics and THD
-
Extech Instruments Corporation
Multifunction Process Calibrator sources and measures Thermocouples (J, K, and T), mA, mV, and V devices. The 24V Loop Supply drives current loads up to 1000 ohms. Memory for 5 user settable output values of each type for fast calibrations. Single/continuous step function for Voltage and Current. Comes complete with six AA batteries and calibration cable with spade lug terminals.
-
AMETEK Sensors, Test & Calibration
Our mA loop calibrator is an economical and easy-to-use calibration device for sourcing and measuring mA signals. Measure and source current to 24 mA and measure voltage to 45 VDC. Combine our 24VDCPS with one of our handheld pressure calibrators to calibrate transmitters in the field.
-
Bestone Industrial Ltd.
It can measure trip-out current, trip-out time, on-line voltage, loop resistance and frequency etc. It’s ideal tool for electrical inspection and repair.Comply with IEC/EN 61010-1 1000V CAT III, 600V CAT IV safety standards.Max common mode voltage: 600V AC RMS.
-
AMETEK Drexelbrook
ThePoint Loop Powered two wire level switch provides a current output and has hazardous area approvals making it a good choice for most of your point level application requirements. ThePoint level sensing device offering is suitable for most temperature, pressure, and material types.
-
RCTi and RCTi 3ph -
Powertek LLC
The RCTi & RCTrms sensors convert ac current to an isolated 0-5V voltage or 4-20mA current loop. TA5V-5A allows compatibility with existing 1A or 5A CT metering circuits. Both offer a choice of proportional (rms) and instantaneous outputs. The available RCT current ranges are 0-100A to 0-50,000Apk. Both RCTi and RCTrms provide accurate measurement over a wide bandwidth ensuring precise measurement even with harmonically distorted wave shapes - using a flexible clip-on sensing coil. The RCTs are available as single and three phase models.
-
Extech 412400 -
Extech Instruments Corporation
The Extech 412400 Multifunction Process Calibrator sources and measures thermocouples (J, K, and T), mA, mV, and V devices. The 24 V loop supply drives current loads up to 1000 ohms. It has memory for 5 user-settable output values of each type for fast calibrations. Single and continuous step function for voltage and current. Comes complete with six AA batteries and a calibration cable with spade lug terminals.